Assessment of Water Chemistry in the Hybrid Cooling System of a Thermal Power Plant Using ICP-MS Analysis and Comparison with EPRI Guidelines

Document Type : Original Article

Authors

1 Faculty Member, Niroo Research Institute, Tehran, Iran

2 Expert, Chemistry and Process Research Group, Tehran, Iran

10.5281/zenodo.21864602
Abstract
Cooling systems in thermal power plants play a decisive role in maintaining steam cycle efficiency, enhancing equipment reliability, and reducing maintenance costs. The chemical quality of water in these systems is one of the most critical factors affecting corrosion rates, scale formation, and heat transfer degradation. In the present study, the water chemistry and corrosion behaviour in the hybrid (dry-wet) cooling system of a sample thermal power plant were investigated. Sampling was conducted on demineralised water, recirculating water of the dry tower, inlet water to heat exchangers, wet tower water, and makeup water. General parameters including pH, electrical conductivity, TDS, temperature, and salinity were measured. Additionally, the concentrations of metallic elements were determined using ICP-MS. The results indicated that the demineralised water exhibits exceptionally high purity and is virtually devoid of metal ions, whereas in the dry cycle, a significant increase in aluminium concentration up to approximately 260 ppb was observed, indicative of active corrosion in the aluminium radiators of the dry tower. In contrast, in the wet tower, the concentrations of calcium, sodium, potassium, silica, copper, and zinc increased markedly, attributable to evaporation, concentration of dissolved solids, and the use of wastewater as make-up water. Comparison of the results with EPRI guidelines revealed that although iron and copper levels fall within acceptable ranges, the elevated aluminium concentration may be regarded as the primary indicator of heat transfer equipment degradation. Accordingly, the revision of the water chemistry control programme, continuous monitoring of dissolved aluminium, and reassessment of the dry tower operating conditions are proposed as the most critical management strategies. The findings of this research can serve as a basis for the development of intelligent corrosion monitoring programmes in power plants equipped with hybrid cooling systems.

Graphical Abstract

Assessment of Water Chemistry in the Hybrid Cooling System of a Thermal Power Plant Using ICP-MS Analysis and Comparison with EPRI Guidelines

Keywords

Subjects

[1]    EPRI. Cycle Chemistry Guidelines for Fossil Plants, 2021.
[2]    EPRI. Condenser and Feedwater System Integrity Guidelines, 2015.
[3]    Davis J.R. Corrosion of Aluminum and Aluminum Alloys. ASM International, 2018.
[4]    Song G., Atrens A. Corrosion Mechanisms of Aluminum Alloys. Progress in Materials Science, 2020.
[5]    Yousefpour A, Mehdizadeh M, Ghasemi Nejad H, Esmaeilpour M, Abdi N, Valaee M, Esmaeilzadeh M. Investigating corrosion caused by improper operation in CWT regime of a combined cycle power plant; Causes and solutions.
[6]    Ghahraman Afshar M, Esmaeilpour M, Ghasemi Nejad H, Esmaeili N. Detection and Analysis of Microbial Influenced Corrosion in Cooling Tower of Shahid Mofateh Power Plant. Journal of New Materials. 2023 Jan 21;13(50):46-59.
[7]    Maul Betsch J., DiFilippo M. Hybrid Cooling Technologies for Power Plants, EPRI Report.
[8]    Turner D. et al. Trace Metal Monitoring in Power Plant Water Chemistry. Power Plant Chemistry, 2019.
[9]    Panagopoulos A. Wastewater Reuse in Thermal Power Plants. Journal of Cleaner Production, 2023.
IEA. Water and Energy Nexus Report, 2022.